Resistance range | 0.1Ω~100Ω other resistance values can be negotiated and ordered |
Resistance accuracy | ±1%~±5% |
Temperature Coefficient | ≤±150ppm/°C (25°C~100°C) |
Load power | Cooling water conductivity requirements: <0.5μS/cm |
Cooling water temperature requirement: outlet water temperature ≤65°C (avoid boiling of water) | |
The formula for calculating the temperature rise of cooling water: ΔT=(P*60)/(L*4200) | |
Where P: Rated power (W) L: Water flow rate (L/min) | |
According to the above requirements, when the inlet water temperature is ≤50°C and the cooling water temperature rise is ≤15°C, the relationship between the water flow rate and the rated power is as follows: | |
6L/min: Pmax=6KW (Inlet and outlet water pressure difference ≤1.2bar, reference value) | |
8L/min: Pmax=8KW (Inlet and outlet water pressure difference ≤1.7bar, reference value) | |
Short-term overload | 1.5 times the rated power, 5s, ΔR≤±(1%R+0.05Ω) |
Maximum peak voltage | 8.5KV |
Insulation withstand voltage | 11kVrms,50Hz,1min |
Space distance | Minimum 17 mm |
inductance | ≤10uH |
Distributed capacitance (Mass) | ≤100pF |
Vibration test | Amplitude 0.75, frequency 10~55 Hz, 2h, ΔR≤±(1%R+0.05Ω) |