Thyratrons use deuterium as arc discharge dielectric,which have the advantages of high working voltage,high pulse current,quick and steady fire lighting,low trigger voltage,high efficiency,long life,light weigh,small size,easy for
Application:
thyratrons are widely used in scientific research,medical treatment and industry such fields,which include laser instruments,radar,pulse modulator,medical linear accelerator,tommy bar protection and other electric instruments and equipments.
Anode Characteristics
Peak Forward Anode Voltage: 35kV
Peak Forward Anode Current: 5kA
Peak Anode Voltage : 18kV
Peak Anode Current: 2.5kA
Average Anode Current: 2A
Anode Current Pulse Duration: 0.35us
Anode Dissipation Factor: 50×10(9)
Anode Current Rate of Rise: 5×10(10) A/s [1]
Grid 2 Drive
Peak Open Circuit Trigger Voltage : 500V ~ 1500V
Driver Circuit Output Impedance: 25Ω ~ 250Ω
Driver Pulse Rise Time: 0 ~ 150 ns
Driver Pulse Width: 1 us ~ 2 us
Bias Voltage (negative): 0 ~ 300 V
Anode Delay Time: 0 ~ 500ns
Anode Delay Time Drift: 0 ~ 150ns
Grid 1 DC Drive
DC grid 1 unloaded priming voltage : 0 ~ 300V
DC grid 1 priming current: 50mA ~ 100 mA
Mechanical Characteristics
Dimension and tube connections: See dimensional date
Net weight: About 1500g
Mounting position: Any [2]
Cooling way: Forced-air or liquid immersion [3]
Notes
[1] This rate of rise refers to that part of the leading edge of the pulse between 26% and 70%of the pulse amplitude.
[2] The tube must be mounted by means of its cathode mounting flange.
[3] The temperature of the envelope must not exceed the value specified below.
Ceramic, anode and grids below 150℃. Cathode mounting flange and base below 120℃.